Control Page
The Control Page contains various parameters which control miscellaneous functions.
To access the Control Page, enter the Setup Mode. Press the Page key until Control is
displayed. Press the Menu key. Each parameter can be changed by pressing the Menu
key until the desired parameter is displayed, and then pressing the keys to change
the value.
Set cycle time in seconds for
control output
Maximum value for all high limit
setpoints
If=0, high limit setpoint= Control
Hi-Lim SP If>0, high limit
setpoint= Control SP* + Band
Off, 3°C to 11°C (5°F to 20°F)
Controls response to loss of
power
Stop, Restart, Hold, Resume
Control aborts to Stopped mode if
power is lost for time period
longer then set value
Allows mode to automatically
start when power is first applied
Operating mode for powerup start
Off, Manual, Timer, Pro-1 to Pro-8
Hysteresis for all alarms and
temperature events
1°C to 56°C (1°F to 100°F)
Process value for retransmit
output = 1VDC
-73°C to 760°C (-100°F to 1400°F)
Process value for retransmit
output = 5VDC
-73°C to 760°C (-100°F to 1400°F)
Time scale setting for program
and timer mode**
Internal beeper sounds when key
is pressed
Internal beeper sounds at end of
cycle
Internal beeper sounds for alarms
* includes ramping setpoints during profiles and controlled ramps
** power fail recovery time limit is always MM:SS regardless of time scale setting
*** high limit setpoint is a read-only item which is calculated on Enable page