ADDRESS LIST Modbus Programming Manual
46 Version 2
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
The auto hold type is not recognized
The auto hold value is not within input span
The events are not within range
There are no more segments available
The number of parameters to be written are invalid for
the function requested
The setpoint value entered was out of bounds. It has
been clamped within the units setpoint limits.
2.9.5.10. Reading a Profile Header (Command Code RP)
Read A Profile Header - Request (to instrument)
The ID address of the instrument
Requires the multi read/write function
Read Start Address High Byte
Read Start Address Low Byte
Read Quantity Of Registers High Byte
Read Quantity Of Registers Low Byte
Write Start Address High Byte
Write Start Address Low Byte
Write Quantity Of Registers High Byte
Write Quantity Of Registers Low Byte
Number of the profile to read
The instrument replies to the Read A Profile Header request as follows:
Read Profile Header - Response (from instrument)
The ID address of the instrument
The multi read/write function
The ASCII codes equivalent to each of the
16 characters of the profile name, e.g. :
A = 65dec / 0x41, B = 66dec / 0x42 etc
a = 97dec / 0x61, b = 98dec / 0x62
The space character (32dec / 0x20hex) is