ADDRESS LIST Modbus Programming Manual
48 Version 2
Copyright © 2012 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
Read A Segment - Request (to instrument)
Read Quantity Of Registers High Byte
Read Quantity Of Registers Low Byte
Write Start Address High Byte
Write Start Address Low Byte
Write Quantity Of Registers High Byte
Write Quantity Of Registers Low Byte
Number of the profile to read
Number of the segment to read
The instrument replies to the Read A Segment request as follows:
Read A Segment - Response (from instrument)
The ID address of the instrument
The multi read/write function
Command Response High Byte
Command Response Low Byte
Echo of the profile number requested
Echo of the segment number requested
0 = Ramp Time, 1 = Ramp Rate,
2 = Step, 3 = Dwell, 4 = Hold, 5 = Loop
6 = Join, 7 = End, 8 = Repeat sequence
then end
Segment Info A (Byte 4 - High)
The meaning of the data contained in
Segment Info A depends on the type of
segment it relates to. See below.
Segment Info A (Byte 1 - Low)
Segment Info B (Byte 4 - High)
The meaning of the data contained in
Segment Info B depends on the type of
segment it relates to. See below.
Segment Info B (Byte 1 - Low)
0 = Auto-Hold Off, 1 = Hold above SP,
2 = Hold below SP,3 - Hold above and
below SP